SpectrUs – lightweight dual-head wireless ultrasound scanner with excellent image quality and high frame rate, suitable for cardiac imaging, enabling sector scan with its convex head. Charging cradle for quick and cable-less charging included.
Discover the next generation of portable ultrasound with SpectrUs, designed to deliver exceptional imaging across diverse medical applications.
Compact, lightweight, and packed with advanced features, SpectrUs empowers healthcare providers to diagnose and treat patients with speed and precision.
Key Features:
- Three-in-One Functionality: Combines linear, convex, and sector scanning in a single device for unmatched versatility.
- Ultra-Lightweight Design: Weighing just 220g, SpectrUs is among the lightest portable ultrasound probes available.
- Extended Battery Life: Optimized power consumption provides up to 2.5 hours of continuous scanning.
- Wireless Charging Case: Smart and portable charging solution for ultimate convenience.
- Advanced Imaging Features: Color Doppler, Modes like Pierce Assist (needle guidance), Anatomical M Mode (customizable sampling lines), Wide View Mode (large field-of-view imaging), CE Mode (contrast-enhanced ultrasound), and TDI Mode (tissue Doppler imaging)
With its compact design, advanced imaging capabilities, and wireless connectivity, SpectrUs empowers healthcare providers to deliver faster, more accurate diagnoses wherever their patients need them. From routine exams to specialized assessments, SpectrUs is your trusted partner in portable ultrasound.
CE/FDA registration pending.

SpectrUs C60L40 Set includes:
- SpectrUs C60L40 scanner/transducer
- SpectrUs Case C60L40 storage box and charging cradle (all in one)
- packing box
Detailed system specifications and comparison with other systems see here (soon)
-
Imaging Modes
Open or CloseAndroid OS application
iOS application
Windows OS application
- B
- B+M
- M
- Compound for linear head
- Color Doppler (CFM)
- Power Doppler (PDI)
- Directional Power Doppler (DPDI)
- Pulsed Wave Doppler (PWD)
- B+PWD (Duplex)
- B+CFM/PDI/DPDI+PWD (Triplex)
- Inverted Tissue Harmonic Imaging (ITHI)
- Needle Enhance mode (NE)
- Puncture assist mode (Pierce)
- B
- B+M
- M
- Compound for linear head
- Color Doppler (CFM)
- Power Doppler (PDI)
- Directional Power Doppler (DPDI)
- Pulsed Wave Doppler (PWD)
- B+PWD (Duplex)
- B+CFM/PDI/DPDI+PWD (Triplex)
- Inverted Tissue Harmonic Imaging (ITHI)
- Needle Enhance mode (NE)
- Puncture assist mode (Pierce)
- B
- B+M
- M
- Compound for linear head
- Color Doppler (CFM)
- Power Doppler (PDI)
- Directional Power Doppler (DPDI)
- Pulsed Wave Doppler (PWD)
- B+PWD (Duplex)
- B+CFM/PDI/DPDI+PWD (Triplex)
- Inverted Tissue Harmonic Imaging (ITHI)
- Needle Enhance mode (NE)
- Puncture assist mode (Pierce)
-
Display Perfomance
Open or CloseAndroid OS application
iOS application
Windows OS application
- ultrasound image size: automatically adjustable to screen resolution
- full screen mode
- cineloop recording/play
- zoom mode
- "Freeze" mode
- "Auto Freeze" mode
- ultrasound image size: automatically adjustable to screen resolution
- full screen mode
- cineloop recording/play
- zoom mode
- "Freeze" mode
- "Auto Freeze" mode
- ultrasound image size: automatically adjustable to screen resolution
- full screen mode
- cineloop recording/play
- zoom mode
- "Freeze" mode
- "Auto Freeze" mode
-
Scanning Methods
Open or Close- electronic linear
- electronic convex
- phased array
- scanning depth selection:
Android OS application
iOS application
Windows OS application
- Linear head: 20-150mm
- Convex head: 40-300mm
- Phased array head: 40-300mm
- Linear head: 20-150mm
- Convex head: 40-300mm
- Phased array head: 40-300mm
- Linear head: 20-150mm
- Convex head: 40-300mm
- Phased array head: 40-300mm
-
Transducers
Open or Close- multifrequency
- supported frequencies:
Android OS application
iOS application
Windows OS application
- Linear head: from 5,0 MHz to 12,0 MHz
- Convex head: from 2.5 MHz to 6.0 MHz
- Phased array head: from 2.5 to 6.0 MHz
- Linear head: from 5,0 MHz to 12,0 MHz
- Convex head: from 2.5 MHz to 6.0 MHz
- Phased array head: from 2.5 to 6.0 MHz
- Linear head: from 5,0 MHz to 12,0 MHz
- Convex head: from 2.5 MHz to 6.0 MHz
- Phased array head: from 2.5 to 6.0 MHz
-
Color Doppler (CFM/PDI/DPDI)
Open or CloseAndroid OS application
iOS application
Windows OS application
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- PRF values, phased array head: 0.5-5.0 kHz
- angle steering for linear head: up to ±20°
- gain control
- wall filter settings, linear head: 8 steps
- Doppler frequency selection: 4 frequencies
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- PRF values, phased array head: 0.5-5.0 kHz
- angle steering for linear head: up to ±20°
- gain control
- wall filter settings, linear head: 8 steps
- Doppler frequency selection: 4 frequencies
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- PRF values, phased array head: 0.5-5.0 kHz
- angle steering for linear head: up to ±20°
- gain control
- wall filter settings, linear head: 8 steps
- Doppler frequency selection: 4 frequencies
-
Pulsed Wave Doppler (PWD)
Open or CloseAndroid OS application
iOS application
Windows OS application
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- Frequency selection: 4 frequencies
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- Frequency selection: 4 frequencies
- PRF values, linear head: 0.5-8.4 kHz
- PRF values, convex head: 0.5-5.0 kHz
- Frequency selection: 4 frequencies
-
Focusing
Open or CloseAndroid OS application
iOS application
Windows OS application
- transmit: variable, 8 zones
- receive: point to point, dynamic
- transmit: variable, 8 zones
- receive: point to point, dynamic
- transmit: variable, 8 zones
- receive: point to point, dynamic
-
Processings
Open or CloseAndroid OS application
iOS application
Windows OS application
- TGC Control, 8 sliders
- dynamic range, 15 values
- overall gain control
- M - mode sweep speed control
- bi-linear interpolation
- speckle reduction and structure improvement
- TGC Control, 8 sliders
- dynamic range, 15 values
- overall gain control
- M - mode sweep speed control
- bi-linear interpolation
- speckle reduction and structure improvement
- TGC Control, 8 sliders
- dynamic range, 15 values
- overall gain control
- M - mode sweep speed control
- bi-linear interpolation
- speckle reduction and structure improvement
-
DICOM
Open or CloseAndroid OS application
iOS application
Windows OS application
- connection to DICOM server
- connection to DICOM server
- connection to DICOM server
-
Functions
Open or CloseAndroid OS application
iOS application
Windows OS application
- touch screen operation
- vertical and horizontal screen orientation
- image and video save
- vascular puncture guidelines
- biopsy guidelines
- full screen and window mode
- touch screen operation
- vertical and horizontal screen orientation
- image and video save
- vascular puncture guidelines
- biopsy guidelines
- full screen and window mode
- touch screen operation
- image and video save
- vascular puncture guidelines
- biopsy guidelines
- full screen and window mode
-
General Measurements and packages
Open or CloseAndroid OS application
iOS application
Windows OS application
- B and Color Doppler mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- M mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Heart Rate
- B and Color Doppler mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- M mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Heart Rate
- B and Color Doppler mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- M mode general measurements and calculations:
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Heart Rate
- Packages:
- Abdomen
- Obstetrics
- Gynecology
- Cardiology
- Vascular
- Small Parts
- Urology
- Musculosceletal
-
PW mode Measurements
Open or CloseAndroid OS application
iOS application
Windows OS application
- PW mode general measurements and calculations
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Acceleration
- Heart Rate
- PS/ED
- PW mode general measurements and calculations
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Acceleration
- Heart Rate
- PS/ED
- PW mode general measurements and calculations
- Distance
- Area
- Angle
- IMT
- Volume
- A/B Length
- A/B Girth
- A/B Area
- Velocity
- Acceleration
- Heart Rate
- PS/ED
-
Power
Open or Close- battery
- wireless charging
- charging case
- operating time from a full battery charge: 2.5 hours (b-mode, continuous scanning, linear head)
-
Dimensions, Weight, Drawings
Open or Close- Height: 160 mm
- Width: 70 mm
- Depth: 30 mm
- Weight: 220 g
-
Recommended Computer Configuration
Open or CloseAndroid OS application
iOS application
Windows OS application
- Mobile phone/Tablet
- Android OS ver.10 or newest
- ARM64 CPU
- RAM >= 2 Gb
- ROM >= 10 Gb
- Screen Physical Size >= 4.7 inches
- Screen Resolution >= 1024 x 720
iPhone, iPad- Windows® OS computer
- Windows® 10/11 (64-bit)
- monitor, IPS technology, resolutions:
- 1080 x 1920
- 1800 x 1200
- 1920 x 1080
- 1920 x 1200
- 1920 x 1280
- CPU i5/i7/i9 >= 2.0 GHz
- RAM >= 8 Gb
- internal Solid State Drive (SSD) >= 256 Gb
- W-Fi adapter